Englander 25-CB120 Pellet Stove ESW0023
- Unit price
- / per
Product Description
The Englander 25-CB120 pellet stove was aptly named for its innovation -
With a simple and intuitive control board, all it takes is pressing the On button, setting the desired room temperature, and walking away. The auto-ignition system guarantees safe lighting, and the control system ensures a safe and efficient burn. A substantial 120 lb capacity hopper provides enough pellet fuel for overnight burns and minimizes manual loading, while the large viewing glass with air wash system allows a beautiful view of the fire.
This stove can heat up to 2,200 sq. ft., and a fresh air hook-up kit is included at no charge. Its stylish nickel cool-touch handle and arched cast iron door add elegance, and it's approved for mobile homes.
Features
- Manufactured in the USA
- Equipped with a Built-in Thermostat
- Capable of heating 2,200 sq. ft.
- Hopper capacity: 120 lb of wood pellets
- Burn time: Up to 65 hours
- High Efficiency and Low Emissions: EPA latest certification
- Approved for Mobile Homes
- Outside Air Kit: Included
Specifications
Specifications | |
---|---|
Fuel type (12) | Premium Grade Wood Pellets |
Recommended heating area (10) | Up to 2,200 ft² |
Hopper capacity | 120 lb |
Maximum burn time (10) | 72 h |
Maximum heat input rate (4) | 32,680 BTU/h (9.58 kW) |
Minimum overall heat output rate (5) | 11,993 BTU/h (3.52 kW) |
Maximum overall heat output rate (5) | 23,466 BTU/h (6.88 kW) |
Minimum average overall efficiency (HHV) (6) (8) | 81.20 % |
Maximum average overall efficiency (LHV) (6) (7) | 72.50 % |
Optimum efficiency (2) | |
Optimum heat transfer efficiency (9) | 75.90 % |
Burn rate | 1.70 - 3.80 lb/h |
Average particulate emission rate (3) | 1.37 g/h |
Average CO (11) | 16.25 g/h |
Average electrical power consumption for ignition cycle (1) | 5.71A (661 W) |
Average electrical power consumption for continuous operation (1) | 3.21A |
Size | Large |
Alcove installation approved | No |
Mobile home approved | No |
High-efficiency certified appliance | Yes, EPA 2020 approved |
Combustion technology | Top-feed |
Baffle type | Mild steel |
Flue outlet diameter | 3" |
Chimney diameter | 3" | 4" |
Type of chimney | ULC/ORD-C441, CAN/ULC S609, UL 641 (TYPE L) |
Overall dimension (Width) | 24 1/2" |
Overall dimension (Height) | 36" |
Overall dimension (Depth) | 27" |
Premium quality blower included (CFM) | 110 CFM included |
Voltage and frequency | 120 VAC / 60 Hz |
Door type | Single, glass with cast iron frame |
Glass type | Ceramic glass |
Glass surface - W x H | 12 1/2" x 13" |
Canadian Standard (emissions) | CSA B415.1-10 |
USA Standard (emissions) | EPA, ASTM E2779 |
Canadian Standard (safety) | ULC S627 |
USA Standard (safety) | UL 1482, ASTM E1509 |
Certified according to applicable standards | By an accredited laboratory (CAN/USA) |
Warranty | 5 years limited |
Shipping weight | 280 lb |
CLEARANCE TO COMBUSTIBLES* | Canada | United States |
---|---|---|
Clearance - Back wall | 0" | 0" |
Clearance - Side wall | 10" | 10" |
Clearance - Corner | 10" | 10" |
Clearance - Base of the unit to ceiling** | 84" | 84" |
*The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and/or web sites).
**Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.
1. Unless stated otherwise, measures were taken directly at the main power source and include all electrical components present in the appliance.
2. Optimum overall efficiency at a specific burn rate (LHV).
3. This appliance is officially tested and certified by an independent agency.
4. Based on the maximum burn-rate and a dry energy value of pellet at 8,600 BTU/lb.
5. As measured per CSA B415.1-10 stack loss method.
6. Efficiency based on radiated and delivered heat when allowing cycling from high to low burn to simulate thermostat demand.
7. Lower Heating Value of the fuel.
8. Higher Heating Value of the fuel.
9. The optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the solid fuels into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.
10. Recommended heating area and maximum burn time may vary subject to location in home, chimney draft, heat loss factors, climate, fuel type, feed rate, fuel level, and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature considering that the space configuration and the presence of heat distribution systems have a significant impact in making heat circulation optimum.
11. Carbon monoxyde.
12. Grades of pellet fuel are determined by organizations such as Pellet Fuels Institute (PFI), ENplus and CANplus.
Englander 25-CB120 Pellet Stove ESW0023
- Unit price
- / per
Handling Time:
Product Ships as soon as the next day! Normal time is 1-4 Business Days.
Shipping Time:
Please Allow 5-8 Business Days for Delivery. Freight Orders Include FREE Delivery Appointment.
Please call, chat, or e-mail us to inquire.
Warranty: See Warranty Registration Page
Not Quite Ready to Get Your Product Delivered?
Want to take advantage of a current sale but not ready to receive an item? No problem! All orders receive special attention and we can hold items for as long as you need! Please Contact Us for more details!
Adding product to your cart
You may also like
Product Description
The Englander 25-CB120 pellet stove was aptly named for its innovation -
With a simple and intuitive control board, all it takes is pressing the On button, setting the desired room temperature, and walking away. The auto-ignition system guarantees safe lighting, and the control system ensures a safe and efficient burn. A substantial 120 lb capacity hopper provides enough pellet fuel for overnight burns and minimizes manual loading, while the large viewing glass with air wash system allows a beautiful view of the fire.
This stove can heat up to 2,200 sq. ft., and a fresh air hook-up kit is included at no charge. Its stylish nickel cool-touch handle and arched cast iron door add elegance, and it's approved for mobile homes.
Features
- Manufactured in the USA
- Equipped with a Built-in Thermostat
- Capable of heating 2,200 sq. ft.
- Hopper capacity: 120 lb of wood pellets
- Burn time: Up to 65 hours
- High Efficiency and Low Emissions: EPA latest certification
- Approved for Mobile Homes
- Outside Air Kit: Included
Specifications
Specifications | |
---|---|
Fuel type (12) | Premium Grade Wood Pellets |
Recommended heating area (10) | Up to 2,200 ft² |
Hopper capacity | 120 lb |
Maximum burn time (10) | 72 h |
Maximum heat input rate (4) | 32,680 BTU/h (9.58 kW) |
Minimum overall heat output rate (5) | 11,993 BTU/h (3.52 kW) |
Maximum overall heat output rate (5) | 23,466 BTU/h (6.88 kW) |
Minimum average overall efficiency (HHV) (6) (8) | 81.20 % |
Maximum average overall efficiency (LHV) (6) (7) | 72.50 % |
Optimum efficiency (2) | |
Optimum heat transfer efficiency (9) | 75.90 % |
Burn rate | 1.70 - 3.80 lb/h |
Average particulate emission rate (3) | 1.37 g/h |
Average CO (11) | 16.25 g/h |
Average electrical power consumption for ignition cycle (1) | 5.71A (661 W) |
Average electrical power consumption for continuous operation (1) | 3.21A |
Size | Large |
Alcove installation approved | No |
Mobile home approved | No |
High-efficiency certified appliance | Yes, EPA 2020 approved |
Combustion technology | Top-feed |
Baffle type | Mild steel |
Flue outlet diameter | 3" |
Chimney diameter | 3" | 4" |
Type of chimney | ULC/ORD-C441, CAN/ULC S609, UL 641 (TYPE L) |
Overall dimension (Width) | 24 1/2" |
Overall dimension (Height) | 36" |
Overall dimension (Depth) | 27" |
Premium quality blower included (CFM) | 110 CFM included |
Voltage and frequency | 120 VAC / 60 Hz |
Door type | Single, glass with cast iron frame |
Glass type | Ceramic glass |
Glass surface - W x H | 12 1/2" x 13" |
Canadian Standard (emissions) | CSA B415.1-10 |
USA Standard (emissions) | EPA, ASTM E2779 |
Canadian Standard (safety) | ULC S627 |
USA Standard (safety) | UL 1482, ASTM E1509 |
Certified according to applicable standards | By an accredited laboratory (CAN/USA) |
Warranty | 5 years limited |
Shipping weight | 280 lb |
CLEARANCE TO COMBUSTIBLES* | Canada | United States |
---|---|---|
Clearance - Back wall | 0" | 0" |
Clearance - Side wall | 10" | 10" |
Clearance - Corner | 10" | 10" |
Clearance - Base of the unit to ceiling** | 84" | 84" |
*The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and/or web sites).
**Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.
1. Unless stated otherwise, measures were taken directly at the main power source and include all electrical components present in the appliance.
2. Optimum overall efficiency at a specific burn rate (LHV).
3. This appliance is officially tested and certified by an independent agency.
4. Based on the maximum burn-rate and a dry energy value of pellet at 8,600 BTU/lb.
5. As measured per CSA B415.1-10 stack loss method.
6. Efficiency based on radiated and delivered heat when allowing cycling from high to low burn to simulate thermostat demand.
7. Lower Heating Value of the fuel.
8. Higher Heating Value of the fuel.
9. The optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the solid fuels into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.
10. Recommended heating area and maximum burn time may vary subject to location in home, chimney draft, heat loss factors, climate, fuel type, feed rate, fuel level, and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature considering that the space configuration and the presence of heat distribution systems have a significant impact in making heat circulation optimum.
11. Carbon monoxyde.
12. Grades of pellet fuel are determined by organizations such as Pellet Fuels Institute (PFI), ENplus and CANplus.