Drolet Escape 1200 Wood Stove
- Unit price
- / per
Meet the Escape 1200, our compact yet powerful model tailor-made for heating residences spanning up to 1,200 square feet. Boasting an impressive EPA-approved status with only 1.8 g/h of particulate emissions, this wood stove pumps out a substantial 45,000 BTU/h. Featuring a deeper base that accumulates more ash, it offers the convenience of less frequent emptying. In straightforward terms, the Escape 1200 embodies durability and dependability.
Included: pedestal, air deflector, ceramic glass, cast iron door with adjustable hinges, ash lip, air damper
- Up to 5 hours burn time
- Up to 17" logs
- 1.55 ft³ firebox
- EPA certified
- Proudly made in Canada
- Limited lifetime warranty
- Certified for mobile home and alcove installation
- Weight : 270 lbs
Details
Features
SPECIFICATIONS
Fuel type | Dry cordwood (16" recommended) |
Recommended heating area (9) | 250 - 1,200 ft² |
Overall firebox volume | 1.7 ft³ |
EPA loading volume | 1.55 ft³ |
Maximum burn time (9) | 5 h |
Maximum heat output-dry cordwood (4) | 45,000 BTU/h (13.19 kW) |
Minimum overall heat output rate (4) (5) | 12,124 BTU/h (3.55 kW) |
Maximum overall heat output rate (4) (5) | 26,700 BTU/h (7.83 kW) |
Average overall efficiency-dry cordwood (HHV) (5) (6) | 74 % |
Average overall efficiency-dry cordwood (LHV) (5) (7) | 79 % |
Optimum efficiency (1) (2) | 80 % |
Optimum heat transfer efficiency (8) | 79 % |
Average particulate emission rate (3) | 1.8 g/h |
Average CO (10) | 74 g/h |
Size | Small |
Alcove installation approved | Yes |
Mobile home approved | Yes, with fresh air intake |
Premium quality blower included (CFM) | Optional |
Certified according to applicable standards | By an accredited laboratory (CAN/USA) |
Combustion technology | Non-catalytic |
Stainless-steel secondary-air system | Yes |
Flue outlet diameter | 6" |
Distance-center of the flue outlet to back unit | 6 5/8" |
Distance-center of the flue outlet to side unit | 9 1/4" |
Chimney diameter | 6" |
Type of chimney | CAN/ULC S629, UL 103 HT (2100 °F) |
Minimum chimney height | 12' |
Overall dimension (Width) | 18 1/2" |
Overall dimension (Depth) | 28 7/8" |
Overall dimension (Height) | 30 1/8" |
Door type | Single, glass with cast iron frame |
Door opening size (Width) | 12" |
Door opening size (Height) | 7 5/8" |
Glass type | Ceramic glass |
Firebox size (Width) | 14 1/4" |
Firebox size (Height) | 11 3/4" |
Firebox size (Depth) | 19 1/8" |
Maximum log length | 17" |
Log positioning | Loading over depth |
Firebox lined with refractory bricks | Yes |
Baffle type | High quality vermiculite |
High-efficiency certified appliance | Yes, EPA 2020 approved |
Canadian Standard (emissions) | CSA B415.1-10 |
USA Standard (emissions) | EPA |
Canadian Standard (safety) | ULC S627 |
USA Standard (safety) | UL 1482, UL 737 |
Steel thickness-body | 3/16" |
Steel thickness-top | 1/4" |
Warranty | Limited lifetime |
Shipping weight | 262 lb (119 kg) |
CLEARANCE TO COMBUSTIBLES*
Applies to 84" ceiling installation only.
Canada | United States | |||
Single wall pipe | Double wall pipe | Single wall pipe | Double wall pipe | |
Clearance - Back wall | 14" | 6" | 12" | 6" |
Clearance - Side wall | 18" | 18" | 18" | 18" |
Clearance - Corner | 11" | 7" | 11" | 7" |
Clearance - Base of the unit to ceiling** | 84" | 84" | 84" | 84" |
*The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and/or web sites).
**Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.
1. Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content between 19% and 25%.
2. Optimum overall efficiency at a specific burn rate (LHV).
3. This appliance is officially tested and certified by an independent agency.
4. The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³. Other performances are based on a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.
5. As measured per CSA B415.1-10 stack loss method.
6. Higher Heating Value of the fuel.
7. Lower Heating Value of the fuel.
8. The optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the solid fuels into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.
9. Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.
10. Carbon monoxyde.
Drolet Escape 1200 Wood Stove
- Unit price
- / per
Handling Time:
Product Ships as soon as the next day! Normal time is 1-4 Business Days.
Shipping Time:
Please Allow 5-8 Business Days for Delivery. Freight Orders Include FREE Delivery Appointment.
Please call, chat, or e-mail us to inquire.
Warranty: See Warranty Registration Page
Not Quite Ready to Get Your Product Delivered?
Want to take advantage of a current sale but not ready to receive an item? No problem! All orders receive special attention and we can hold items for as long as you need! Please Contact Us for more details!
Adding product to your cart
You may also like
Meet the Escape 1200, our compact yet powerful model tailor-made for heating residences spanning up to 1,200 square feet. Boasting an impressive EPA-approved status with only 1.8 g/h of particulate emissions, this wood stove pumps out a substantial 45,000 BTU/h. Featuring a deeper base that accumulates more ash, it offers the convenience of less frequent emptying. In straightforward terms, the Escape 1200 embodies durability and dependability.
Included: pedestal, air deflector, ceramic glass, cast iron door with adjustable hinges, ash lip, air damper
- Up to 5 hours burn time
- Up to 17" logs
- 1.55 ft³ firebox
- EPA certified
- Proudly made in Canada
- Limited lifetime warranty
- Certified for mobile home and alcove installation
- Weight : 270 lbs
Details
Features
SPECIFICATIONS
Fuel type | Dry cordwood (16" recommended) |
Recommended heating area (9) | 250 - 1,200 ft² |
Overall firebox volume | 1.7 ft³ |
EPA loading volume | 1.55 ft³ |
Maximum burn time (9) | 5 h |
Maximum heat output-dry cordwood (4) | 45,000 BTU/h (13.19 kW) |
Minimum overall heat output rate (4) (5) | 12,124 BTU/h (3.55 kW) |
Maximum overall heat output rate (4) (5) | 26,700 BTU/h (7.83 kW) |
Average overall efficiency-dry cordwood (HHV) (5) (6) | 74 % |
Average overall efficiency-dry cordwood (LHV) (5) (7) | 79 % |
Optimum efficiency (1) (2) | 80 % |
Optimum heat transfer efficiency (8) | 79 % |
Average particulate emission rate (3) | 1.8 g/h |
Average CO (10) | 74 g/h |
Size | Small |
Alcove installation approved | Yes |
Mobile home approved | Yes, with fresh air intake |
Premium quality blower included (CFM) | Optional |
Certified according to applicable standards | By an accredited laboratory (CAN/USA) |
Combustion technology | Non-catalytic |
Stainless-steel secondary-air system | Yes |
Flue outlet diameter | 6" |
Distance-center of the flue outlet to back unit | 6 5/8" |
Distance-center of the flue outlet to side unit | 9 1/4" |
Chimney diameter | 6" |
Type of chimney | CAN/ULC S629, UL 103 HT (2100 °F) |
Minimum chimney height | 12' |
Overall dimension (Width) | 18 1/2" |
Overall dimension (Depth) | 28 7/8" |
Overall dimension (Height) | 30 1/8" |
Door type | Single, glass with cast iron frame |
Door opening size (Width) | 12" |
Door opening size (Height) | 7 5/8" |
Glass type | Ceramic glass |
Firebox size (Width) | 14 1/4" |
Firebox size (Height) | 11 3/4" |
Firebox size (Depth) | 19 1/8" |
Maximum log length | 17" |
Log positioning | Loading over depth |
Firebox lined with refractory bricks | Yes |
Baffle type | High quality vermiculite |
High-efficiency certified appliance | Yes, EPA 2020 approved |
Canadian Standard (emissions) | CSA B415.1-10 |
USA Standard (emissions) | EPA |
Canadian Standard (safety) | ULC S627 |
USA Standard (safety) | UL 1482, UL 737 |
Steel thickness-body | 3/16" |
Steel thickness-top | 1/4" |
Warranty | Limited lifetime |
Shipping weight | 262 lb (119 kg) |
CLEARANCE TO COMBUSTIBLES*
Applies to 84" ceiling installation only.
Canada | United States | |||
Single wall pipe | Double wall pipe | Single wall pipe | Double wall pipe | |
Clearance - Back wall | 14" | 6" | 12" | 6" |
Clearance - Side wall | 18" | 18" | 18" | 18" |
Clearance - Corner | 11" | 7" | 11" | 7" |
Clearance - Base of the unit to ceiling** | 84" | 84" | 84" | 84" |
*The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and/or web sites).
**Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.
1. Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content between 19% and 25%.
2. Optimum overall efficiency at a specific burn rate (LHV).
3. This appliance is officially tested and certified by an independent agency.
4. The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³. Other performances are based on a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.
5. As measured per CSA B415.1-10 stack loss method.
6. Higher Heating Value of the fuel.
7. Lower Heating Value of the fuel.
8. The optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the solid fuels into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.
9. Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.
10. Carbon monoxyde.